Analog control module for one feed axis with standard interface, containing speed and current control as well as monitoring of tachometer, rotor position encoder and motor temperature. Current limit, controller gain, smoothing and operating mode are set with DIL switches on the board, and the setpoint and enable signals are connected via terminal strips X321 and X331. Test sockets provide the current and speed actual values, and two red LEDs indicate encoder faults and axis faults.
General
| Manufacturer | Siemens |
| Type / model | Analog feed control, 1-axis, standard interface |
| Article number | 6SN1118-0AD11-0AA0 |
| Order number | 6SN1118-0AD11-0AA0 |
| Series | SIMODRIVE 611 analog |
| Condition | Used |
Technical data
| Version | feed drive control, analog, 1-axis, standard interface |
| Motors according to manufacturer | 1FT5 servomotors with tachometer and rotor position encoder |
| Combinable power modules | 1-axis 8, 15, 25, 50, 80, 160 and 200 A, resulting inverter currents 4/8 A to 100/200 A |
| Setting elements | DIL switch S2 with 10 contacts (direction of rotation, current normalization 100 to 23%, current controller gain 0.5 to 11.5, speed- or current-controlled), S3 with 8 contacts (smoothing, speed controller adaptation, ready or fault signal, I component in current-controlled mode), S1 for tachometer adaptation |
| Smoothing | selectable, speed setpoint 2.2 ms, speed actual value 280 µs, speed controller 370 µs, current setpoint 110 µs |
| Terminal strip X321 | AS1/AS2 checkback contact start inhibit (relay, 250 V AC/1 A, 30 V DC/2 A), terminal 663 pulse enable (+21 to 30 V), terminal 9 enable voltage +24 V |
| Terminal strip X331 | 56.1/14.1 speed or current setpoint as differential input 0 to ±10 V, 65.1 controller enable and 22.1 select current control (each +13 to 30 V), 9 enable voltage +24 V |
| Common-mode range of the differential input | ±24 V to PE |
| Cross-section of the signal terminals | max. 1.5 mm² |
| Test sockets | W current actual value ±10 V at Imax, T current setpoint ±10 V at Imax, X speed actual value ±10 V at rated speed, M reference ground, output resistance 10 kΩ each |
| Indicators | red LED H2 motor encoder fault (tachometer, rotor position encoder), red LED H1 axis fault (speed controller at its limit, heatsink temperature, motor overtemperature, I²t monitoring) |
| Motor temperature monitoring | evaluation of the PTC thermistors in the motor winding, response temperature 150 °C, signal without shutting down the drive |