| Number of inputs | 16 for voltage, current and thermocouples, 8 for resistance measurement |
| Voltage ranges | ±25 mV, ±50 mV, ±80 mV, ±250 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, ±10 V, 1 to 5 V, input resistance 1 MΩ |
| Current ranges | 0 to 20 mA, 4 to 20 mA, ±5 mA, ±10 mA, ±20 mA, input resistance 50 Ω |
| Thermocouples | type B, E, J, K, L, N, R, S, T, U |
| Resistance thermometers | Pt 100, Pt 200, Pt 500, Pt 1000, Ni 100, Ni 1000 |
| Resistance ranges | 0 to 48 Ω, 0 to 150 Ω, 0 to 300 Ω, 0 to 600 Ω, 0 to 6000 Ω (usable up to 5000 Ω) |
| Resistance measurement | two-, three- or four-wire connection, constant current typ. 1.67 mA |
| Transducers | two-wire and four-wire transducers |
| Reference junction compensation | configurable, external with Pt 100 or compensating box, dynamic reference temperature value |
| Linearization | configurable for thermocouples and resistance thermometers |
| Measuring principle | integrating |
| Resolution | 16 bits including overrange |
| Integration time | 2.5/16.7/20 ms, configurable (interference frequency suppression 400/60/50 Hz) |
| Basic conversion time | 6/20.1/23.5 ms |
| Basic execution time of all channels | 96/322/376 ms |
| Smoothing of measured values | configurable in 4 levels |
| Noise suppression | common mode > 100 dB (UCM < 120 Vpp), series mode > 40 dB, crosstalk between inputs > 70 dB |
| Operational error limit | ±0.3% at ±250 mV to ±10 V and all current ranges, ±0.31% at ±80 mV, ±0.32% at ±50 mV, ±0.35% at ±25 mV |
| Basic error limit at 25 °C | ±0.15% at ±250 mV to ±10 V and all current ranges, ±0.17% at ±80 mV, ±0.19% at ±50 mV, ±0.23% at ±25 mV |
| Temperature error | ±0.004 %/K |
| Load voltage L+ | 24 V DC, only for supplying two-wire transducers, reverse polarity protection |
| Current consumption from backplane bus | max. 700 mA |
| Current consumption from L+ | max. 400 mA with 16 fully driven two-wire transducers |
| Power loss | typ. 4.5 W |
| Electrical isolation | channels to backplane bus and to load voltage L+ yes, between channels no |
| Isolation test voltage | 2120 V DC between bus and L+/M, bus and analog section, analog section and ground, L+/M and ground, 500 V DC between bus and ground and between analog section and L+/M |
| Destruction limit | voltage input 18 V continuous, 75 V for 1 ms (mark to space ratio 1:20), current input 40 mA |
| Shielded cable length | max. 200 m, max. 50 m with thermocouples and ranges up to 80 mV |
| Interrupts | diagnostic interrupt, limit value interrupt, hardware interrupt at end of cycle, each configurable |
| Indicators | LED INTF (internal fault, red), LED EXTF (external fault, red) |
| Dimensions (W × H × D) | 25 × 290 × 210 mm |
| Weight | approx. 500 g |