| Product version according to data sheet | functional status 01, firmware V2.6 |
| Supply voltage | 24 V DC (20.4 to 28.8 V) |
| External protection (recommendation) | min. 2 A |
| Current consumption | 650 mA rated value, typ. 100 mA at no load, inrush current typ. 2.5 A (I²t 1 A²s) |
| Power loss | typ. 3.5 W |
| Work memory | 256 KByte for program and data, not expandable |
| Load memory | plug-in Micro Memory Card, max. 8 MByte, data retention min. 10 years after the last programming |
| Backup | maintenance-free via the Micro Memory Card, program and data without battery |
| Processing times | typ. 0.1 µs per bit operation, 0.2 µs per word operation, 2 µs fixed-point arithmetic, 3 µs floating-point arithmetic |
| Blocks | total 1024 DBs, FBs and FCs, max. 16 KByte each, DB numbers 1 to 1023, FB and FC numbers 0 to 2047 |
| Nesting depth | 8 per priority class, additional 4 within an error OB |
| Counters and timers | 256 S7 counters (0 to 999) and 256 S7 timers (10 ms to 9990 s), IEC counters and timers as SFB |
| Flags | 2048 bytes, retentivity adjustable MB 0 to MB 2047 (default MB 0 to MB 15), 8 clock memory bits |
| Retentive data area | max. 128 KByte (incl. timers, counters and flags) |
| Local data | max. 1024 bytes per priority class, max. 510 per block |
| I/O address area | inputs and outputs 2 KByte each, of which distributed 2 KByte each, process image 2048 bytes each |
| Digital channels | 16384 inputs and outputs each, of which central max. 1024 each |
| Analog channels | 1024 inputs and outputs each, of which central max. 256 each |
| Configuration | max. 4 racks with 8 modules each, max. 3 expansion units, 1 integrated and up to 4 further DP masters via CP, recommended up to 8 FM, 8 CP PtP and 10 CP LAN |
| Clock | hardware clock, retentive and synchronizable, backup time 6 weeks at 40 °C, deviation max. 10 s per day |
| Interface X1 | MPI/PROFIBUS DP, RS 485, isolated, max. 12 Mbit/s, 16 connections as MPI |
| PROFIBUS DP master | max. 124 DP slaves, equidistance, isochronous mode (OB 61), SYNC/FREEZE, DPV1 |
| PROFIBUS DP slave | max. 12 Mbit/s, transfer memory 244 bytes each for inputs and outputs, direct data exchange |
| Interface X2 | PROFINET, RJ45, isolated, 10/100 Mbit/s with automatic detection |
| PROFINET IO controller | max. 128 IO devices, update time 1 to 512 ms, 2 KByte each for inputs and outputs |
| Open communication | TCP/IP via the PROFINET interface, max. 8 connections, max. 1460 bytes |
| Safety-related communication | PROFIsafe |
| Connections | 16 in total |
| Diagnostic buffer | 100 entries |
| Configuration software | STEP 7 V5.4 SP2 or higher with S7 Distributed Safety V5.4 or higher |
| Programming languages | LAD, FBD, STL, SCL, CFC, GRAPH, HiGraph |
| Approvals | TÜV type examination certificate (functional safety), FM and CCC-Ex for hazardous locations, maritime CCS and NK |
| Dimensions (W × H × D) | 80 × 125 × 130 mm |
| Weight | approx. 460 g |