| Size | 3 |
| Version | standard version (00), option cards can be installed (MDX61), version B |
| Part number | 827 964 0 |
| Operating quadrants | four-quadrant operation with brake chopper (4) |
| Line-side radio interference suppression | none (0), limit value class C1 to EN 61800-3 only with corresponding line filter |
| Recommended motor power | 15 kW at constant load, 22 kW at variable torque load or constant load without overload |
| Line voltage | 3 × AC 380 to 500 V (to EN 50160) |
| Line frequency | 50 to 60 Hz ±5% |
| Nominal supply current | AC 28.8 A (100%), AC 36 A (125%) at 3 × AC 400 V |
| Apparent output power | 22.2 kVA at 3 × AC 380 to 500 V and 4 kHz |
| Rated output current | AC 32 A at 3 × AC 400 V |
| Continuous output current | AC 40 A (125%) at 4 kHz, AC 32 A (100%) at 8 kHz, each at 3 × AC 400 V |
| Current limitation | motor and regenerative 150% of rated current, duration depending on capacity utilization, internally adjustable 0 to 150% |
| Minimum brake resistance | 15 Ω in four-quadrant operation |
| Output voltage | max. supply voltage |
| Switching frequency | 4, 8, 12 or 16 kHz adjustable |
| Speed range | −6000 to +6000 min⁻¹, resolution 0.2 min⁻¹ across the entire range |
| Operating mode | continuous operation with 50% overload capacity |
| Power loss | 550 W at rated output power and 4 kHz |
| Cooling | forced cooling with temperature-controlled fan (response threshold 45 °C), cooling air consumption 180 m³/h |
| Power terminals X1 to X4 | M6 screw with washer, max. 25 mm², crimp cable lug to DIN 46234, tightening torque 3.5 Nm |
| Setpoint input | AI11/AI12 on X11, differential input 0 to +10 V or −10 to +10 V (12 bit) or 0 to 20 mA or 4 to 20 mA (11 bit) |
| Reference voltages | REF1 +10 V and REF2 −10 V on X11, max. 3 mA |
| Binary inputs | DIØØ to DIØ5 on X13, DIØ6 and DIØ7 on X16, isolated via optocoupler, PLC-compatible to EN 61131, Ri approx. 3 kΩ, DIØØ fixed to controller inhibit |
| Binary outputs | DBØØ brake (max. 150 mA) and DOØ2 on X10, DOØ3 to DOØ5 on X16, DOØ2 to DOØ5 max. 50 mA, short-circuit proof |
| Relay output | DOØ1 on X10 with common contact, N/O and N/C contact, DC 30 V, max. 800 mA |
| Auxiliary voltage output | VO24 DC 24 V, max. 400 mA |
| External voltage supply | VI24 on X10, DC 24 V −15% to +20% to EN 61131-2 |
| System bus | SBus on X12, CAN to specification 2.0 parts A and B, ISO 11898, max. 64 stations, terminating resistor 120 Ω via DIP switch |
| Serial interface | RS485 on X13, 9.6 kbaud, max. 32 stations, max. 200 m |
| Motor temperature input | TF/TH/KTY on X10, response threshold at 2.9 kΩ ±10% |
| Safety contact X17 | input for safe stop DC 24 V (SVI24), power consumption 7.5 W for size 3 |
| Slots | fieldbus slot, expansion slot, encoder slot, XT for DBG60B keypad or UWS21B interface |
| Display | 7-segment display |
| Memory card | pluggable, included in the scope of delivery according to the operating instructions |
| Degree of protection | IP20 |
| Operating ambient temperature | 0 to +50 °C at 100% continuous current and 4 kHz, 0 to +40 °C at 125% and 4 kHz or at 100% and 8 kHz, current derating 2.5% per K from 40 to 50 °C and 3% per K from 50 to 60 °C |
| Storage and transport temperature | −25 to +70 °C (EN 60721-3-3, class 3K3) |
| Operating altitude | up to 1000 m without restrictions, from 1000 to max. 4000 m current derating 1% per 100 m, from 2000 m additional voltage derating AC 6 V per 100 m |
| Dimensions (W × H × D) | 200 × 465 × 308 mm |
| Weight | 15.0 kg |