| Command communication | parallel interface and stepper motor interface on X15, plus analog interface and RS232/RS485 |
| Line voltage | 1 × AC or 3 × AC (200 to 480 V) ±10% |
| Line frequency | (50 to 60) ±2 Hz |
| Peak current 1 (type current) | 40 A, peak value |
| Peak current 2 | 16 A at 4 kHz, 12.5 A at 8 kHz switching frequency, peak values |
| Continuous current 1 | 13 A at 4 kHz, 9 A at 8 kHz switching frequency, peak values |
| Continuous current 2 | 16 A at 4 kHz, 12.5 A at 8 kHz switching frequency, peak values |
| Switching frequency | 4 or 8 kHz, selectable |
| Maximum output frequency | 400 Hz at 4 kHz, 800 Hz at 8 kHz switching frequency |
| Power loss | 180 W at continuous current 2, excluding the continuous power of the internal braking resistor |
| Peak braking power | 10 kW at 850 V DC bus voltage, load cycle 0.5 s on and 33 s off |
| Continuous braking power | 0.15 kW at ambient temperature up to 45 °C |
| Maximum braking energy | 5.0 kWs |
| DC bus voltage | DC 300 to 800 V, depending on the line voltage |
| DC bus capacitance | 0.27 mF ±20 % |
| DC bus continuous power with single source supply | max. 1.3 kW at 3 × AC 400 V, max. 1.5 kW at 3 × AC 480 V, each up to 45 °C |
| Cooling | internal fan for power section and braking resistor, approx. 24 m³/h |
| Control voltage | DC 19.2 to 28.8 V on X1 |
| Power consumption of control section | 19 W without external load on control outputs and encoder interface 2 |
| Parallel interface X15 | 25-pin D-sub socket, 10 inputs I0 to I9 (16 to 30 V, 13.3 kΩ), 10 outputs Q0 to Q9 (max. 80 mA, short-circuit proof) |
| Stepper motor inputs | SM1 and SM2 on X15, isolated differential inputs, RS422 compatible, max. 1 MHz |
| Digital inputs | on X3 home switch, positive and negative limit switch, two probe or cam inputs, E-stop and clear error (16 to 30 V) |
| Digital outputs | on X3 ready, warning and UD message (max. 80 mA, short-circuit proof) |
| Analog inputs | 2 differential inputs ±10 V on X3, 12 bit, 40 kΩ, cut-off frequency 800 Hz |
| Analog outputs | 2 outputs ±10 V on X3, max. 2 mA, 8 bit, without short-circuit protection |
| Serial interface | RS232 or RS485 on X2 (15-pin D-sub socket), RS232 at 9600 or 19200 baud |
| Encoder input X4 | encoder 1 for digital servo feedback (DSF/HSF) or resolver |
| Encoder input X8 | encoder 2 for sine encoder 1 Vpp, EnDat encoder, gear-type encoder 1 Vpp or square-wave encoder 5 V TTL |
| Firmware | not included in the type (FW), firmware module in slot X7 for the programming module |
| Operating and display elements | diagnostic display H1, button S1 for clearing errors, address switches S2 and S3 |
| Degree of protection | IP20 |
| Operating ambient temperature | +5 to +45 °C for rated output, +45 to +55 °C with derating of 2% per °C |
| Storage and transport temperature | −30 to +85 °C |
| Operating altitude | up to 1000 m for rated output, max. 2000 m |
| Relative humidity | max. 95 % |
| Dimensions (W × H × D) | 65 × 360 × 261 mm, overall dimensions according to dimension drawing |
| Weight | 5.7 kg |