| Rated output capacity | 5.5 kW |
| Maximum output capacity | 11 kW |
| Main circuit power supply | 200/220/230 V AC +10%/−15%, three-phase, 50/60 Hz ±1 Hz |
| Control power supply | 200/220/230 V AC +10%/−15%, single-phase, 50/60 Hz ±1 Hz |
| Power equipment capacity, main circuit | 9 kVA |
| Power equipment capacity, control power | 0.7 kVA |
| Control method | regenerative control (power supply regeneration) |
| Input voltage series | 200 V input series |
| Total heat dissipation | 100 W |
| Remaining heat in cabinet | 53 W with natural ventilation, 47 W with forced air cooling of at least 2 m/s |
| Cooling | heat sink projects through the rear wall of the cabinet |
| Connections | TB2 mains input L1, L2, L3, TB1 DC link L+ and L−, CX1A control power input, CX1B control power output, CX2B 24 V and emergency stop signal, CX3 magnetic contactor control, CX4 emergency stop contact, JX1B interface to the amplifier modules |
| AC reactor | A81L-0001-0122, always required according to the manual |
| Circuit breakers and contactor according to manufacturer | circuit breaker main circuit 30 A, control circuit 5 A, magnetic contactor 30 A |
| Transformer for 380 to 460 V AC | A06B-6052-J001, 10 kVA, primary 380/415/460 V AC, secondary 200 V AC, optional |
| Boards according to maintenance manual | wiring board A16B-2202-0460, printed circuit board A16B-2202-0420 |
| Dimensions (H × W × D) | 380 × 90 × 307 mm |
| Weight | 6.3 kg |
| Operating ambient temperature | 0 to 55 °C at the unit, 0 to 45 °C in the cabinet |
| Storage and transport temperature | −20 to 60 °C |
| Relative humidity | normally max. 90%, no condensation |
| Vibration in operation | below 0.5 G |